Grouped equipment
Low temperature constant temperature reaction bath
The low temperature constant temperature reaction bath is a new type of experimental instrument produced by our factory with reference to the products of Tokyo Chemical and Chemical Equipment Co., Ltd., which is especially suitable for organic synthesis and chemical reaction under closed conditions. It is an experiment of modern chemistry, biopharmaceutical and chemical pharmacy. Required equipment.
First, the characteristics:
1. It adopts fully enclosed compressor refrigeration, featuring fast cooling, low noise, advanced performance and reliable quality.
2, the bottom is equipped with a heating system, using heating balance cooling, avoiding the frequent start of the compressor, increasing the life of the compressor.
3, digital display temperature control, PID adjustment increases the temperature control accuracy, so that the temperature is controlled at ± 0.5 ° C.
As shown in Figure 4, the parts in contact with the liquid are all made of stainless steel, which has anti-corrosion, anti-rust and anti-cold liquid pollution functions.
5. The bottom is equipped with magnetic stirring, and the magnetic stirring in the tank is carried out to make the temperature fully uniform, and the distance between the stirring magnet and the stirring rod is increased, and the stirring force is increased.
Precautions:
Please read the precautions carefully before using this instrument.
★Power supply
The power supply of this machine must use standard 220V or 380V, should have a reasonable grounding system, and be equipped with a standard three-pole safety socket.
Except for the factory-equipped plugs of the factory, the other plugs must not be connected externally, please use the air switch!
★Media
With ethanol or methanol, do not allow sand or debris to enter the cooling system or circulation pump to prevent blockage.
★ line connection
Use three-phase power supply to prevent the host from burning due to wrong connection. If you do not understand, please consult us in time.
★ ventilation protection
There should be a venting hole around the instrument. There should be enough space for good dustproof. Keep the instrument away from the heating equipment and avoid direct sunlight.
★ temperature and humidity
The normal working room temperature range of the instrument is ≤25°C, and the humidity range is ≤60°C. Exceeding this range will affect the safety performance and performance of the instrument.
★ Instrument movement
It is strictly forbidden to move or tilt the instrument at random after the liquid tank is filled. The liquid in the tank may flow into the machine and cause danger or damage to the machine. Indoor open fires are strictly prohibited.
★Maintenance
Do not open and repair the instrument without undue damage. In case of failure, professional technicians should come to the door for repair.
Send Us Message
Your message was sent successfully.
Sorry!Something Went Wrong.